ISI-501 series

500W True Sine Wave DC-AC Inverter with MPPT Solar Charger

Features
 True sine wave output(THD<3%)
 High surge power up to 1000W
 High efficiency up to 88%
 High-frequency design
 Thermostatically controlled cooling fan
 Protections: Bat. low alarm / Bat. low shutdown/ Over temperature / Output short / Input polarity reverse / Overload /
 Built-in 500W MPPT solar charger, MPPT efficiency: 98%(Typ.)
 Built-in remote ON-OFF control
 Built-in battery low relay contact
 LED indicator for operation status and battery capacity
 3 years warranty

ISI-501 series

ORDER NO.ISI-501-112ISI-501-124ISI-501-148ISI-501-212ISI-501-224ISI-501-248

OUTPUT

RATED POWER450W500W500W450W500W500W
MAXIMUM OUTPUT POWER (Typ.)
550W for 60 sec. / surge power 1000W for 30 cycles (112, 212 models : 495W for 60 sec. / surge power 900W for 30 cycles)
AC VOLTAGE
Factory setting set at 110VAC
Factory setting set at 230VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W
200 / 220 / 230 / 240VAC selectable by setting button S.W
FREQUENCY
60Hz 0.5Hz
50Hz 0.5Hz
60+-0.1Hz 50/60Hz selectable by setting button S.W
50+- 0.1Hz 50/60Hz selectable by setting button S.W
WAVEFORM
True sine wave (THD<3%)
True sine wave (THD<3%)
AC REGULATION± 3%± 3%± 3%± 3%± 3%± 3%
FRONT PANEL INDICATOR
Fault and operation status, Charger status, Battery capacity

INPUT

BAT. VOLTAGE12V24V48V12V24V48V
VOLTAGE RANGE (Typ.) 10.5 ~ 15VDC21 ~ 30VDC42 ~ 60VDC10.5 ~ 15VDC21 ~ 30VDC42 ~ 60VDC
DC CURRENT (Typ.) 50A30A15A50A30A15A
NO LOAD CURRENT DRAW1.25A0.63A 0.32A 1.25A 0.63A 0.32A
OFF MODE CURRENT DRAW≦1mA≦1mA≦1mA≦1mA≦1mA≦1mA
EFFICIENCY (Typ.)85%87%87%86%88%88%